Skip to main content

For pathology labs and diagnostic centres

Samples in, checked reports out

Track every sample with a barcode, enter results against structured reference ranges, have a different person approve them and issue a PDF report that can be verified by QR code.

From sample to report

  1. Book and collect

    Create a booking from your test catalogue or packages, collect the sample and print its barcode label.

  2. Process

    The processing board shows where every sample is. Each step is recorded.

  3. Enter results

    Technicians enter values. The server flags each one as normal, high, low or critical against the reference range, and a critical value raises an alert.

  4. Approve independently

    A pathologist or lab admin approves. By default the person who entered the results cannot approve them. Approval is blocked while a critical alert is unacknowledged.

  5. Release and share

    A versioned PDF with your letterhead and a QR code is issued. Secure links need the patient's recorded consent, expire, and ask for the last four digits of the mobile number.

Illustration with made-up sample data. Flags come from the reference ranges you set; they are not a diagnosis.

What is included

Barcoded samples

Code 128 labels and a recorded history for every sample.

Reference ranges and flags

Structured ranges per test. Flags are computed on the server, not typed in.

Critical alerts

Critical values raise an alert that must be acknowledged, with a note of who was informed.

Independent approval

Entry and approval are separate permissions, and technicians never hold approval rights.

Amendments with review

Released results change only through a recorded amendment that produces a new version marked AMENDED. Old PDFs stay retrievable.

QR-verified reports

Each report carries a QR code to a public page that confirms authenticity without showing patient data.

Consent-gated sharing

Report links and WhatsApp messages need consent on record, and withdrawing consent switches them off.

Catalogue import

Load about 15 common starter tests, or import your own test catalogue from Excel or CSV.

Report designer

Set the letterhead, footer note, accent colour and logo. Reports already issued are never re-rendered.

What you can do on day one

  • Load the starter test catalogue and review its reference ranges.
  • Add your technicians, pathologists and front desk with the right roles.
  • Set your report letterhead and the pathologist's credentials.
  • Create a sample booking and take it from collection to a released report.
  • Import your own tests or patients from Excel or CSV.

Good to know

  • Reference ranges in the starter catalogue are a starting point. Your pathologist must review them before real use.
  • The software flags values; it does not interpret them or give clinical advice.
  • It does not hold any laboratory accreditation or certification on your behalf.

Also see

See how it fits your practice.

Start a free trial in minutes, or talk to us and we will walk you through your own workflow.